The device has improved gain output stages to achieve high output level even in case of low OMI values. It contains a CM5 configuration module which enables the full segmentated operation mode for both forward and return path (2 transmitter and 2 receiver modules). In basic configuration the device contains 2 optical receiver modules and 2 transmitter modules and of course the configuration module. This node contains two WWDM filters beside the optical modules.
Benefits :-
• Low noise optical receiver module
• Return path optical transmitter module
• Segmentation in forward and return path
• Pull-out internal casting tray electronics
• 2 high-leveled RF outputs (splittable to 2x2)
• Remote powered switching power supply
• Status monitoring option
• Built-in WWDM filters
TECHNICAL SPECIFICATIONS___________________________________________________________
Optical receiver parameters
Bandwidth [MHz] 47...1000
Wavelength [nm] 1290…1570
Optical input level range [dBm] -5…+3
Nominal optical input level [dBm] 0
Optical input return loss [dB] > 45
Equivalent input noise [pA/√Hz] 7
RF level on the output of the receiver module
(-5..+3dBm Popt and 4% OMI) [dBµV] 78 ±1
Optical connector type SC/APC
Optical transmitter parameters
Bandwidth [MHz] 5-65
Wavelength [nm] 1550, 1570 (CWDM)
Optical input level range [mW] 2
Optical connector type SC/APC
RF input level(1) [dBµV] 78 ±1
Flatness [dB] ±0,5
Input return loss (40 MHz -1,5 dB/octave) [dB] > 18
Input impedance [Ω] 75
RF level on the testpoint of the optical transmitter(1) [dBµV] 70 +1/-2
RF parameters
Gain [dB] 41
Maximum output level
(EN50083, 2.5% OMI, 79 ch, 8 dB SLOPE, CTB, CSO ≤ -60 dBc) [dBµV] 115
Output testpoint attenuation [dB] 30 ±1
Forward path RF testpoint (4% OMI) [dBµV] 82
Flatness [dB] ±0,7
Output amplifier-module type GaN PD hybrid
Active outputs 2
Output diplex filter [MHz] 65/85
Output return loss (40 MHz -1,5 dB/octave) [dB] > 18
Output impedance [Ω] 75
Isolation between segments (forward path) [dB] > 65
Isolation between segments (return path) [dB] > 75
Breakpoint frequency of TILT [MHz] 606, 750, 862, 1000
General parameters
Screening factor [dB] 80
Maximum power consumption [W] 57
Power supply voltage [V-AC] Object 1 30...65; Object 2 35...90
Maximum current feed-through [A] 10
Hum modulation [dB] 70
Degree of protection IP 65
Temperature range [°C] -20…+50
RF connector type 5/8”
Dimensions [mm] 275x200x175
Weight [kg] 5,0